ultrasound board repair

Aloka UST 5299 Ultrasound Transducer Probe

Lead time: 2-4 days
Warranty: 12 months
Description
Aloka UST-5299 Phased Array Cardiac HST Ultrasound Transducer

1. Type: Phased Array
2. Application: Cardiac, Abdominal
3. Frequency:3.0Mhz
4. Condition: Compatible New
5. Warranty: 12 months
6. Lead Time: Within one week against order confirmation
7. Compatible Systems: SSD-830,SSD-870,SSD-875,SSD-3500,SSD-4000 (reference only and may not be complete).

Other Aloka Probe we can offer:

 
Brand Model Compatible System
Aloka UST-979-3.5 SSD-900/1000/1100/1400/1700/3500/4000    
Aloka UST-944B-3.5 SSD-500/SSD- 620/SSD- 625/SSD-650/SSD-1100
Aloka UST-669-5-7.5 SSD-1000/ SSD -1700/ SSD -2200
Aloka UST-984-5 SSD-1000/SSD-1400/SSD-1700/SSD-5000/SSD-5500
Aloka UST-9115-5 SSD-5000/ Alpha 5/ Alpha 10  
Aloka UST-9116P-5 SSD-1000
Aloka UST-9118 Alpha 5/Alpha 10/SSD-3500/SSD-4000/SSD-5500
Aloka UST-9120 Alpha 5/Alpha 7/Alpha 10
Aloka UST-9121 SSD-3500/SSD-4000
Aloka UST-9123 SSD-4000/ SSD-3500
Aloka UST-9124 SSD-3500/SSD-4000   
Aloka UST-9126 SSD-5000/ SSD-5500/Alpha 5  


Warnings and cautions of ultrasonic probe
 
The ultrasonic probe is a valuable device. It must be careful in the process of use. Avoid dropping, impact, or abrasion to transducers.
When installing or removing the probe, first switch off the power and then operate it carefully.
Avoid rapid and extreme temperature changes, as well as lengthy exposure to direct sunlight or a strong ultraviolet light source.
Do not use sharp objects to penetrate the acoustic lens.Once the acoustic lens is damaged, the coupling gel is easy to enter the interior of the probe and damage the piezoelectric element.
Do not soak transducer in any liquid above the recommended level as stated in the user manual for your system, please operate according to the manufacturer's instructions, otherwise it will lead to circuit failure or even burn out.  
Do not disinfect at high temperature, because the probe is equipped with piezoelectric ceramics, high temperature will weaken the effect.
Before use, carefully check whether the housing and cable are damaged, so as to prevent the probe from high voltage injury.
After the probe is used, the residual coupling gel on the probe must be wiped clean to prevent rats or other animals from gnawing the lens.
 

 
About Us
As one of the leading ultrasound service companies in China, Rongtao Medical provides healthcare solutions, repair service, parts and accessories to hospitals, clinics and distributors world-widely.
Connect with us

Copyright 2014-2023 Guangzhou Rongtao Medical Tech LTD All Rights Reserved.