Hitachi Aloka HI VISION PREIRUS: Image Interference

Repair Guides · Technical article · Updated Jan 31, 2024 · I00153I1

Page summary

Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Article.
  • Relevant system context: Hitachi.
  • Part reference: I00153I1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandHitachi
Part numberI00153I1
Content typeArticle

Technical notes

Technical body content

Fault Phenomenon

The imagine shows hot wheel interference while Hitachi Aloka HI VISION Preirus working, which seriously affect the image diagnosis.

Trouble Shooting and Maintenance

According to the fault phenomenon, the same interference has occurred in each probe of the machine in use, so the possibility of the fault of the color ultrasonic diagnostic apparatus is preliminarily ruled out. According to the safety use specification of the color ultrasonic diagnostic instrument, the ground end of the machine shell and the power plug of the machine should be connected to the ground. The circuit formed due to improper grounding will also cause electromagnetic interference.Then, using the power measuring instrument measuring grounding resistance, normal should be 2 ~ 5 Ω, but on checking ground not installed on the machine;Reinstall the ground after testing ground resistance is 3 Ω, accord with a standard;Boot test, interference disappeared, the problem solved.

Tags and related links

Current internal destinations only

Related pages

Same category, brand, model or tag context
HITACHI ALOKA: Alpha 7 RX board Diagnosis
Repair Guides · Technical article

HITACHI ALOKA: Alpha 7 RX board Diagnosis

Hitachi, Alpha 7, Beamformer / RF Board, PN I00282I1 technical article with photos, part identification, model context and Rongtao quote or repair support.

Updated Mar 19, 2021I00282I12 images
Repair Guides · Technical article

Hitachi ALOKA Alpha 10 system maintenance

Hitachi, Alpha 10, PN I00120I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Jul 8, 2022I00120I1
Repair Guides · Technical article

Hitachi Aloka F75

Hitachi, PN I00197I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Dec 1, 2020I00197I1
GE Logiq S8 Image Interference
Repair Guides · Technical article

GE Logiq S8 Image Interference

GE, LOGIQ S8, PN I00624I1 technical article with photos, part identification, model context and Rongtao quote or repair support.

Updated Feb 27, 2023I00624I12 images
Repair Guides · Technical article

Fault case:Philips HD15 Ultrasound System

Philips, HD15, PN I00281I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Mar 19, 2021I00281I1