hitachi arietta 60 cannot be turned on normally
Repair Cases · Repair case · Reviewed May 18, 2026 · A00145A1
Repair caseText-focused technical page

This page is focused on the technical note, model context and service information rather than product photography.

Page summary
Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Repair Case.
  • Relevant system context: GE VIVID ULTRASOUND.
  • Technical focus: Probe / Transducer.
  • Part reference: A00145A1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandGE
Model / systemVIVID ULTRASOUND · VIVID HITACHI · EPIQ
Part typeProbe / Transducer
Part numberA00145A1
Content typeRepair Case
Technical notes
Technical body content

Failure phenomenon

After the Hitachi ARIETTA 60 machine turned on and displayed the HITACHI logo, the display and touch screen did not display, and the button lights on the control panel flashed cyclically, and the ultrasound interface could not be entered normally.

Failure analysis

1. After the machine is turned on, there is no display after the HITACHI logo appears, and the button light on the control panel flashes cyclically, indicating that the power supply of the machine is normal, and the fault is caused by a problem in the back of the machine. 2. The back end of the machine is composed of BE main board, CELL board and system hard disk. On the right side of the machine, you can see it after opening the casing. First, rule out whether the system is faulty. After replacing the system hard disk, the same fault still exists when the machine is turned on, so the BE motherboard fault is locked. 3. Since the BE motherboard is connected to the front-end TPRB and RDBF boards, you need to remove the front-end board first, and disconnect the other power connections of the BE motherboard. 4. After replacing the BE main board, the machine starts up normally, and all the probes and functions are in normal use.

Summary

After replacing the BE motherboard, the machine resumes normal use.

Service context

Rongtao uses this technical record for GE VIVID ULTRASOUND Probe / Transducer as supporting context for quote intake, photo comparison, board identification and repair-route selection. For live availability, send the machine model, board label, fault symptom and clear photos of both sides of the part.

Tags and related links
Current internal destinations only
Related pages
Same category, brand, model or tag context
Repair case
Repair Cases · Repair case

hitachi aloka noblusbrief introduction

GE, VIVID ULTRASOUND, Probe / Transducer, PN A00126A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00126A1
Repair case
Repair Cases · Repair case

hitachi eub 5500 ultrasound non image

GE, VIVID ULTRASOUND, Probe / Transducer, PN 5500-ULTRASOUND-NON-IMAGE-A00125A1 repair case with part identification, model context and Rongtao quote or.

Reviewed May 18, 20265500-ULTRASOUND-NON-IMAGE-A00125A1
Repair case
Repair Cases · Repair case

hitachi aloka f75

GE, VIVID ULTRASOUND, Probe / Transducer, PN EP556600 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026EP556600