B2B ultrasound repair & partsGlobal shippingEmail quote intakeNeed help? info@rongtaomedical.com
Rongtao Medical
RONGTAO MEDICAL
ULTRASOUND REPAIR · MODEL PAGES · LIVE INVENTORY
Contact Us
technical support common sence of the color ultrasound machine maintenance2
Brand Knowledge · Repair guide · Reviewed May 18, 2026
Page summary
Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Repair Guide.
  • Relevant system context: GE VIVID ULTRASOUND.
  • Technical focus: Probe / Transducer.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandGE
Model / systemVIVID ULTRASOUND · VIVID TECHINICAL · EPIQ
Part typeProbe / Transducer
Conditions permit, the hospital engineer should be invited to follow up and observe
Content typeRepair Guide
Technical notes
Technical body content

Technical notes

Techinical support |Common sence of the color ultrasound machine maintenance(2)

Dust removal

1. Use high pressure fan to remove dust. 2. Key parts of dust removal include: Power cabinet circuit board cabinet filter fan unit 3. Keyboard, TGC controller and trackball 1. Clean the surface and probe of the equipment with a high-quality towel and mild detergent. 2. When cleaning the probe, do not pull the cable. 3. Do not wash the filter with water.If it must be washed, the filter must be fully dried before it is installed on the machine. 4. When using the wet towel, please wring it out to prevent water droplets from entering into the machine.

Reassemble and boot

1. Reassemble the dismantled parts back to the machine. 2. Carefully check the cable connection to ensure it is correct and firm. 3. Check that all removed parts and screws have been installed on the equipment. 4. Reassemble the peripherals and cables to their original state. 5. When starting up, pay attention to the start-up process of the equipment, and then check the function of the system.

Finally

1. The customer representative shall conduct functional tests on the machine to confirm the normal working state of the equipment. 2. Restore the site to its original state and clean it. 3. Precautions: In the above work process, if conditions permit, the hospital engineer should be invited to follow up and observe. Avoid contact with electronic components.If contact components, be sure to use antistatic wrist bands or other effective antistatic measures. Before disassembly, important parts should be photographed or recorded to prevent mistakes in reassembly.

Service context

Rongtao uses this technical record for GE VIVID ULTRASOUND Probe / Transducer as supporting context for quote intake, photo comparison, board identification and repair-route selection. For live availability, send the machine model, board label, fault symptom and clear photos of both sides of the part.

Tags and related links
Current internal destinations only
Related pages
Same category, brand, model or tag context
philips hdi5000 color ultrasonic maintenance
Brand Knowledge · Repair guide

philips hdi5000 color ultrasonic maintenance

GE, VIVID ULTRASOUND, Probe / Transducer, PN HDI5000 repair guide with photos, part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026HDI50002 images
siemens x300 color ultrasonic maintenance2
Brand Knowledge · Repair guide

siemens x300 color ultrasonic maintenance2

GE, VIVID ULTRASOUND, Probe / Transducer repair guide with photos, part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 20262 images
aloka 10 system maintenance
Brand Knowledge · Repair guide

aloka 10 system maintenance

GE, VIVID ULTRASOUND, Probe / Transducer, PN EU-6031 repair guide with photos, part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026EU-60311 images