GE VOLUSON E10:Image is whitish

Repair Cases · Repair case · Reviewed May 18, 2026 · A00142A1

Page summary

Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Repair Case.
  • Relevant system context: GE LOGIQ P5.
  • Technical focus: Beamformer / RF Board.
  • Part reference: A00142A1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandGE
Model / systemLOGIQ P5 · VOLUSON E10
Part typeBeamformer / RF Board
Part numberA00142A1
Conditions, replace the RFM board, and troubleshoot after reinstalling the system
Content typeRepair Case

Technical notes

Technical body content

Failure phenomenon

The scan area image of GE VOLUSON E10 color ultrasound system is whitish, and restarting is invalid.

Troubleshooting

Voluson E10 image problems are common front-end board problems. Diagnose according to the image conditions, replace the RFM board, and troubleshoot after reinstalling the system.

Tips

Poor contact between the various components of the ultrasound equipment is a common cause of failure of the ultrasound system. Dust pollution, contact oxidation, frequent insertion of probes, bumps during use, etc. may all lead to poor contact. Regular dust removal, regular maintenance and preventive maintenance if possible, avoiding human damage as much as possible is an effective way to reduce the failure of the ultrasound system.

Service context

Rongtao uses this technical record for GE LOGIQ P5 Beamformer / RF Board as supporting context for quote intake, photo comparison, board identification and repair-route selection. For live availability, send the machine model, board label, fault symptom and clear photos of both sides of the part.

Tags and related links

Current internal destinations only

Related pages

Same category, brand, model or tag context
Repair Cases · Repair case

Troubleshooting of GE Vivid 7 crashes

GE, VIVID 7, Probe / Transducer, PN GD75232 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026GD75232
Repair Cases · Repair case

ge 9l d probe image interference troubleshooting

GE, VIVID ULTRASOUND, Probe / Transducer, PN A00135A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00135A1
Repair Cases · Repair case

ge logiq e portable ultrasound common failure

GE, LOGIQ E, Probe / Transducer, PN A00122A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00122A1
Repair Cases · Repair case

ge logiq e9 ultrasound machine frequent crashes

GE, LOGIQ E9, Probe / Transducer, PN A00123A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00123A1