B2B ultrasound repair & partsGlobal shippingEmail quote intakeNeed help? info@rongtaomedical.com
Rongtao Medical
RONGTAO MEDICAL
ULTRASOUND REPAIR · MODEL PAGES · LIVE INVENTORY
Contact Us
hitachi eub 5500 ultrasonic troubleshooting3
Brand Knowledge · Repair guide · Reviewed May 18, 2026 · D1858
Repair guideText-focused technical page

This page is focused on the technical note, model context and service information rather than product photography.

Page summary
Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Repair Guide.
  • Relevant system context: GE VIVID ULTRASOUND.
  • Technical focus: Probe / Transducer.
  • Part reference: D1858.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandGE
Model / systemVIVID ULTRASOUND · VIVID HITACHI · EPIQ
Part typeProbe / Transducer
Part numberD1858
Content typeRepair Guide
Technical notes
Technical body content

Fault phenomenon

After the circuit breaker is closed, press the power on key, the machine does not respond, all indicator lights on the operation panel and display are not on, and the fan does not rotate.

Troubleshooting

Measuring power box fuse are normal, measuring input voltage 220V are normal.The 220V voltage is lowered to 110V through the transformer inside the power box and input to the power board. The 110V voltage is measured normally.Two circuit boards were removed from the power box. After careful inspection, it was found that the PNP transistor D1858 on the circuit board was broken. At the same time, it was found that some other components around the transistor were damaged. Hitachi eub-5500 color ultrasound normal boot is divided into two steps.The first step is that the breaker switch is closed and 110V voltage is conducted into the circuit board. At this time, the start circuit in the power box has started to work and is in standby state, waiting for the start signal.The second step is to press the start button, switch and conduction, and send a low-level start signal to inform the power box to start working.The circuit of D1858 is a standby circuit.The standby circuit fault causes the power box to be unable to receive the normal start signal, making the power box unable to start normally.After replacing the D1858 transistor and surrounding components, the machine recovers. This fault is common on Hitachi eub-5500 color ultrasound for two reasons: (1) The operation of the use of habits.After the machine is used every day, the machine is not shut down according to the normal shutdown process, and the circuit breaker switch is not closed after the system is shut down, so that the standby circuit in the power box is always in a live standby state, seriously affecting the life of this part of the circuit. (2) The machine power box did not timely dust, filter screen blockage, power box can not normally heat, resulting in overheating and burnt circuit board.

Service context

Rongtao uses this technical record for GE VIVID ULTRASOUND Probe / Transducer as supporting context for quote intake, photo comparison, board identification and repair-route selection. For live availability, send the machine model, board label, fault symptom and clear photos of both sides of the part.

Tags and related links
Current internal destinations only
Related pages
Same category, brand, model or tag context
Repair guide
Brand Knowledge · Repair guide

hitachi eub 5500 ultrasonic troubleshooting1

GE, VIVID ULTRASOUND, Probe / Transducer, PN 5500-ULTRASONIC-TROUBLESHOOTING1-84 repair guide with part identification, model context and Rongtao quote or.

Reviewed May 18, 20265500-ULTRASONIC-TROUBLESHOOTING1-84
Repair guide
Brand Knowledge · Repair guide

hitachi eub 5500 ultrasonic troubleshooting2

GE, VIVID ULTRASOUND, Probe / Transducer, PN 5500-ULTRASONIC-TROUBLESHOOTING2-85 repair guide with part identification, model context and Rongtao quote or.

Reviewed May 18, 20265500-ULTRASONIC-TROUBLESHOOTING2-85
Repair guide
Brand Knowledge · Repair guide

hitachi eub 5500 ultrasonic troubleshooting4

GE, VIVID ULTRASOUND, Probe / Transducer, PN 5500-ULTRASONIC-TROUBLESHOOTING4-87 repair guide with part identification, model context and Rongtao quote or.

Reviewed May 18, 20265500-ULTRASONIC-TROUBLESHOOTING4-87
Repair guide
Brand Knowledge · Repair guide

hitachi eub 5500maintennance1

GE, VIVID ULTRASOUND, Probe / Transducer, PN 5500MAINTENNANCE1 repair guide with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 20265500MAINTENNANCE1