philips ie33 ultrasonic diagnostic instrument common fault troubleshooting5

Brand Knowledge · Repair guide · Reviewed May 18, 2026

Page summary

Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Repair Guide.
  • Relevant system context: Philips VIVID ULTRASOUND.
  • Technical focus: Probe / Transducer.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandPhilips
Model / systemVIVID ULTRASOUND · VIVID PHILIPS · EPIQ
Part typeProbe / Transducer
Content typeRepair Guide

Technical notes

Technical body content

Technical notes

Philips IE33 ultrasonic diagnostic instrument common fault troubleshooting(5)

Fault phenomenon

Images imported from external media into i-33 cannot be re-exported in any format.

Troubleshooting

The problem is that the system does not allow Imported checks to be exported.Open the import check then Double-click the first image to go to full screen mode. Press the Acquire key on I plus 33, which will Append the check. After that, open each imported image to the full screen, press the Acquire key on positive 33, so that the image can be copied to the new Append check below.Close the Re - view;Open the Review interface, select appended study, and then select Send to Media to export.Open check can also be output in Jpeg/AVI format, problem solved.

Service context

Rongtao uses this technical record for Philips VIVID ULTRASOUND Probe / Transducer as supporting context for quote intake, photo comparison, board identification and repair-route selection. For live availability, send the machine model, board label, fault symptom and clear photos of both sides of the part.

Tags and related links

Current internal destinations only

Related pages

Same category, brand, model or tag context
replace philips hd15 aim board
Brand Knowledge · Repair guide

replace philips hd15 aim board

Philips, VIVID ULTRASOUND, Probe / Transducer, PN 453561197306 repair guide with photos, part identification, model context and Rongtao quote or repair.

Reviewed May 18, 20264535611973061 images
Brand Knowledge · Repair guide

Philips HDI5000 Color Ultrasound Maintenance Case

Philips, VIVID ULTRASOUND, Probe / Transducer, PN HDI5000 repair guide with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026HDI5000