Philips IE33 ultrasonic diagnostic instrument common fault troubleshooting

Repair Guides · Technical article · Updated Aug 27, 2020 · I00099I1

Page summary

Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Article.
  • Relevant system context: Philips iE33.
  • Part reference: I00099I1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandPhilips
Model / systemiE33
Part numberI00099I1
Content typeArticle

Technical notes

Technical body content

Technical notes

Philips IE33 ultrasonic diagnostic instrument common fault troubleshooting

Fault phenomenon

The device failed to start, stopped at the "initializing hardware" screen, or error 606 was reported during startup.

Troubleshooting

The motherboard battery is dead and the BIOS Settings will automatically jump to the Default Settings, which will cause an exception to the HOST or SIP boot.Mainboard battery life is about 5 years, use a multimeter to measure the battery voltage, less than +2.85Vdc, replace the mainboard battery (HOST/SIP mainboard battery model is CR2032, UMB/EMB mainboard battery model is CR2450), and change the BIOS to Philips Settings, troubleshooting.

Tags and related links

Current internal destinations only

Related pages

Same category, brand, model or tag context
Repair Guides · Technical article

Fault case:Philips HD15 Ultrasound System

Philips, HD15, PN I00281I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Mar 19, 2021I00281I1
Repair Guides · Technical article

Philips CX50 report error 0022, can not enter the system

Philips, CX50, PN 0022-CAN-NOT-ENTER-THE-SYSTEM-I00473I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Feb 27, 20230022-CAN-NOT-ENTER-THE-SYSTEM-I00473I1
Repair Guides · Technical article

Philips EPIQ 7: Shows Error "511"

Philips, EPIQ 7, PN I00152I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Jul 8, 2022I00152I1
Repair Guides · Technical article

Philips EPIQ 7C:Time is too long to start up

Philips, EPIQ 7C, PN I00198I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Jan 31, 2024I00198I1
Repair Guides · Technical article

Philips IU22: Abdominal probe PW mode error

Philips, iU22, Probe / Transducer, PN I00236I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Feb 28, 2022I00236I1