GE Voluson E8 Fault: blue screen and file loss
Repair Guides · Technical article · Updated May 7, 2022 · I00119I1
Technical articleText-focused technical page

This page is focused on the technical note, model context and service information rather than product photography.

Page summary
Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Article.
  • Relevant system context: GE VOLUSON E8.
  • Part reference: I00119I1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandGE
Model / systemVOLUSON E8
Part numberI00119I1
Applicationsoftware using the hard disk engraving method to complete the hard disk replacement and tr
Content typeArticle
Technical notes
Technical body content

Fault phenomenon

The machine has a blue screen, reporting that the system file is missing, and it is resolved after reinstalling the system, but this failure recurs after a week.

Troubleshooting

According to the description, reinstalling the system once solved the failure, indicating that it was caused by the computer system software crash, but the same failure occurred one week after it returned to normal. It is suspected that the hard disk may have bad sectors, causing the system files to be lost during startup. Open the panel, remove the hard disk, find a hard disk with the same capacity, and use Ghost to clone a hard disk with the operating system and ultrasound application software using the hard disk engraving method to complete the hard disk replacement and troubleshooting.

Summary

Most medical equipment now uses the Windows platform. The advantage is that it saves manufacturers the cost of developing software and hardware. The disadvantage is that ultrasound system software failures, such as system crashes, occur from time to time. Therefore, at the beginning of the equipment installation, you can consider doing a hard disk clone backup to prevent problems. Once the software fails, you can directly replace the hard disk to ensure the normal operation of the equipment, which not only speeds up the repair speed, but also saves the maintenance cost for the hospital. But pay attention to whether the Ghost version and the original device hard disk use data encryption technology, so as not to cause backup failure, it is recommended to replace the trial after backup to determine the result.

Tags and related links
Current internal destinations only
Related pages
Same category, brand, model or tag context
GE Logiq S8 Image Interference
Repair Guides · Technical article

GE Logiq S8 Image Interference

GE, LOGIQ S8, PN I00624I1 technical article with photos, part identification, model context and Rongtao quote or repair support.

Updated Feb 27, 2023I00624I12 images
Technical article
Repair Guides · Technical article

GE Logiq P5

GE, LOGIQ P5, PN I00196I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Dec 1, 2020I00196I1