GE Voluson E8 Fault: blue screen and file loss

Repair Guides · Technical article · Updated May 7, 2022 · I00119I1

Page summary

Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Article.
  • Relevant system context: GE VOLUSON E8.
  • Part reference: I00119I1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandGE
Model / systemVOLUSON E8
Part numberI00119I1
Applicationsoftware using the hard disk engraving method to complete the hard disk replacement and tr
Content typeArticle

Technical notes

Technical body content

Fault phenomenon

The machine has a blue screen, reporting that the system file is missing, and it is resolved after reinstalling the system, but this failure recurs after a week.

Troubleshooting

According to the description, reinstalling the system once solved the failure, indicating that it was caused by the computer system software crash, but the same failure occurred one week after it returned to normal. It is suspected that the hard disk may have bad sectors, causing the system files to be lost during startup. Open the panel, remove the hard disk, find a hard disk with the same capacity, and use Ghost to clone a hard disk with the operating system and ultrasound application software using the hard disk engraving method to complete the hard disk replacement and troubleshooting.

Summary

Most medical equipment now uses the Windows platform. The advantage is that it saves manufacturers the cost of developing software and hardware. The disadvantage is that ultrasound system software failures, such as system crashes, occur from time to time. Therefore, at the beginning of the equipment installation, you can consider doing a hard disk clone backup to prevent problems. Once the software fails, you can directly replace the hard disk to ensure the normal operation of the equipment, which not only speeds up the repair speed, but also saves the maintenance cost for the hospital. But pay attention to whether the Ghost version and the original device hard disk use data encryption technology, so as not to cause backup failure, it is recommended to replace the trial after backup to determine the result.

Tags and related links

Current internal destinations only

Related pages

Same category, brand, model or tag context
Repair Guides · Technical article

GE Voluson E8 Fault case analysis

GE, VOLUSON E8, PN I00062I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Aug 4, 2020I00062I1
GE Logiq S8 Image Interference
Repair Guides · Technical article

GE Logiq S8 Image Interference

GE, LOGIQ S8, PN I00624I1 technical article with photos, part identification, model context and Rongtao quote or repair support.

Updated Feb 27, 2023I00624I12 images
Repair Guides · Technical article

GE LOGIQ E9: Frequent Crashes

GE, LOGIQ E9, PN I00151I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Oct 16, 2020I00151I1
Repair Guides · Technical article

GE Logiq P5

GE, LOGIQ P5, PN I00196I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Dec 1, 2020I00196I1
Repair Guides · Technical article

GE VIVID I system maintainance

GE, VIVID I, PN I00004I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Jan 30, 2024I00004I1
Repair Guides · Technical article

The GE LOGIQ S8 fails to start

GE, LOGIQ S8, PN I00472I1 technical article with part identification, model context and Rongtao quote or repair support.

Updated Jan 4, 2022I00472I1