philips epiq 7c v6 2 probe artifact

Repair Cases · Repair case · Reviewed May 18, 2026 · A00134A1

Page summary

Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Repair Case.
  • Relevant system context: Philips VIVID ULTRASOUND.
  • Technical focus: Probe / Transducer.
  • Part reference: A00134A1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandPhilips
Model / systemVIVID ULTRASOUND · VIVID PHILIPS · epiq 7c
Part typeProbe / Transducer
Part numberA00134A1
Content typeRepair Case

Technical notes

Technical body content

Failure phenomenon

The 2D image of the Philips EPIQ 7C ultrasonic three-dimensional volume probe V6-2 has an artifact on the right side of the center, and the artifact is more obvious after the image is colored.

Troubleshooting

First swap the slots between V6-2 and C5-1, and observe that the image of C5-1 is normal, and the artifacts in the middle right of the image of V6-2 still exist. It is determined that it is not the problem of the slot interface. Then there may be bubbles in the probe V6-2, select V6-2 for the probe, turn on the 4D mode, let the motor in the probe rotate for a period of time, then switch back to the 2D mode, and hang the probe upside down for a period of time. If there are bubbles, the above two steps are mainly It is to eliminate the bubbles in front of the array element. But image artifacts still exist after the above two steps.Moreover, the artifacts are elongated after painting. In the end, it may be that an array element in the probe is broken. Freeze the machine. Unplug all the probes and U disk to enter the maintenance service interface and perform probe test under Hardware Utilities. Copy out the test log (log) and analyze it. It is found that there are four elements in the probe damaged. In engineering practice, the energy of a single element is small when it is launched. Generally, multiple elements are combined to transmit, which plays a role in controlling the signal. Next, each array element is grouped and combined and excited in a certain way to form different emission beam scanning. If the array element is damaged, part of the image cannot be scanned. The device image returned to normal after the probe was replaced, and there was no failure after a period of trial.

Service context

Rongtao uses this technical record for Philips VIVID ULTRASOUND Probe / Transducer as supporting context for quote intake, photo comparison, board identification and repair-route selection. For live availability, send the machine model, board label, fault symptom and clear photos of both sides of the part.

Tags and related links

Current internal destinations only

Related pages

Same category, brand, model or tag context
Repair Cases · Repair case

philips epiq 7 system reports error quot511quot

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00114A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00114A1
Repair Cases · Repair case

philips epiq 7ctime is too long to start up

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00130A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00130A1
Repair Cases · Repair case

philips hd15 ultrasound system troubleshooting

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00115A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00115A1
Repair Cases · Repair case

philips iu22 abdominal probe pw mode error

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00133A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00133A1
Repair Cases · Repair case

philips iu22 ultrasonic error at boot quot518quot

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00110A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00110A1