philips iu22 abdominal probe pw mode error

Repair Cases · Repair case · Reviewed May 18, 2026 · A00133A1

Page summary

Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Repair Case.
  • Relevant system context: Philips VIVID ULTRASOUND.
  • Technical focus: Probe / Transducer.
  • Part reference: A00133A1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandPhilips
Model / systemVIVID ULTRASOUND · VIVID PHILIPS · EPIQ
Part typeProbe / Transducer
Part numberA00133A1
Content typeRepair Case

Technical notes

Technical body content

Failure phenomenon

The abdomen probe C5-2 used for Philips iU22 ultrasound equipment is checked in 2D mode, the instrument is normal, when switching to PW mode (pulse Doppler), the instrument reports an error, after restarting the machine, the 2D mode is used normally, and the failure of switching PW mode remains. The superficial probe L11-3 is not affected in any way.

Failure analysis

There may be 3 reasons for this failure: 1. Probe failure. 2. Machine system or software problems. 3. The circuit board is faulty.

Maintenance

Replace with another C5-2 probe that is in normal use and perform the same operation, and the fault remains. Remove the probe fault. Performing the instrument self-check and software self-checking did not find any problems, restore the mirror backup software on the machine, the fault persists, and eliminate the system and software problems. Considering the reason of the circuit board, in the process of PW mode switching in C5-2, a group of high voltages will dynamically change. The front-end NewAnalog Input Module (NAIM) analog voltage modulation board is responsible for providing the front-end 320MHz master clock, providing the pulse voltage for exciting the probe, and adjusting And calibrate the high voltage pulse, also generate TGCI, TGC2 waveforms, check the overcurrent, overvoltage, front-end temperature at the same time, and manage all the front-end power supply, so it is considered that the NAIM board may be damaged. Disassemble the front chassis, pull out the NAIM board and find that the bottom filter mesh is too dusty, indicating that the board has a problem with heat dissipation. Observing the NAIM board, it is found that the R650 resistor that controls the high-voltage dynamic change part has an abnormal appearance. The resistance is measured with a multimeter to determine that the resistor is damaged. Clean and maintain the machine, replace it with a new NAIM board and restart it after resetting, the fault disappears.

Service context

Rongtao uses this technical record for Philips VIVID ULTRASOUND Probe / Transducer as supporting context for quote intake, photo comparison, board identification and repair-route selection. For live availability, send the machine model, board label, fault symptom and clear photos of both sides of the part.

Tags and related links

Current internal destinations only

Related pages

Same category, brand, model or tag context
Repair Cases · Repair case

philips hd15 ultrasound system troubleshooting

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00115A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00115A1
Repair Cases · Repair case

philips iu22 ultrasonic error at boot quot518quot

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00110A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00110A1
Repair Cases · Repair case

philips epiq 7 system reports error quot511quot

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00114A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00114A1
Repair Cases · Repair case

philips epiq 7c v6 2 probe artifact

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00134A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00134A1
Repair Cases · Repair case

philips epiq 7ctime is too long to start up

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00130A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00130A1