B2B ultrasound repair & tested partsGlobal shippingEmail quote intakeNeed help? info@rongtaomedical.com
Rongtao Medical
RONGTAO MEDICAL
ULTRASOUND REPAIR · PROBE SOLUTIONS · TESTED PARTS
Contact Us

repair case philips iu22 screen flickering

Repair Cases · Repair case · Reviewed May 18, 2026 · A00117A1

Page summary

Key service context for quote intake and technical review
  • Published in the Rongtao Medical Blog under Repair Case.
  • Relevant system context: Philips VIVID ULTRASOUND.
  • Technical focus: Probe / Transducer.
  • Part reference: A00117A1.
  • Use this page to compare product, repair and troubleshooting context before opening a quote request.
BrandPhilips
Model / systemVIVID ULTRASOUND · VIVID REPAIR · EPIQ
Part typeProbe / Transducer
Part numberA00117A1
Content typeRepair Case

Technical notes

Technical body content

Failure phenomenon

The screen of the Philips IU22 color Doppler ultrasound device is blurred and there are black vertical lines, and the fault still exists after multiple restarts.

Failure analysis

The screen position covers the scanning fan-shaped area of ​​Philips color Doppler ultrasound, so it is speculated that the reasons include the following aspects: First, the display fails. Second, the PC graphics card is faulty. Third, the video conversion board is faulty.

Troubleshooting

First, verify whether the display is malfunctioning. The result of using the monitor shows the same failure, so the monitor problem can be eliminated. Second, verify whether there is a problem with the video conversion board. If you use VGA to connect to the workstation, if there is still a problem with the screen, you can troubleshoot the converter board. Third, determine whether there is a problem with the PC graphics card. Remove the color Doppler ultrasound PC graphics card of the same model and install it on the faulty machine. As a result, the fault disappears and it can be determined that there is a graphics card problem. The color Doppler ultrasound PC host is a special customized component. The graphics card is different from the commonly used computer, and it is difficult to buy similar products in the market. By observing the surface of the graphics card, it is found that the capacitor is swollen. After replacing the capacitor, troubleshoot the problem.

Service context

Rongtao uses this technical record for Philips VIVID ULTRASOUND Probe / Transducer as supporting context for quote intake, photo comparison, board identification and repair-route selection. For live availability, send the machine model, board label, fault symptom and clear photos of both sides of the part.

Tags and related links

Current internal destinations only

Related pages

Same category, brand, model or tag context
Repair Cases · Repair case

philips hd15 ultrasound system troubleshooting

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00115A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00115A1
Repair Cases · Repair case

philips iu22 abdominal probe pw mode error

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00133A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00133A1
Repair Cases · Repair case

philips iu22 ultrasonic error at boot quot518quot

Philips, VIVID ULTRASOUND, Probe / Transducer, PN A00110A1 repair case with part identification, model context and Rongtao quote or repair support.

Reviewed May 18, 2026A00110A1